Infrastructure of Data Centers (IDC)

 

Who should attend

  • IT managers whose data center has to reach the level of performance and availability required by their enterprise.
  • Real estate managers who have to be ready for new power and thermal management required today
  • Integrators who offer owner assistance and project management in line with international standardization and assure the sustainability of the proposed and installed solution.
  • Manufacturers, their marketing, training, engineering and commercial staffs to integrate their solutions in this new environment.

Prerequisites

This training requires a basic level for power, network cabling system over copper and fiber optics.

Course Content

The information technology, initially to the automation of repetitive tasks of internal accounting dedicated, is now at the heart of the commercial or technical business throughout the world. Equipment manufacturers meet this new burden of data processing by the marketing of ever more powerful and consumer of energy computers. These equipments require entirely new computer rooms or data centers. Most of data centers don’t meet these new technologies and are daily taking risks, including the major risk which is the total shutdown. This training meets all the concerns generated by the weak infrastructures of data centers, and can prepare for any refurbishment or new design with the main objectives of sustainability, availability and reduced energy consumption by more and more expensive. This formation provides you the knowledge and skills related to data centers infrastructures, urbanization, the pooling of different systems implemented, and their operation.

Course Outline
Introduction to data centers

  • What is a data center according to the standard
  • What are the different systems constituting the infrastructure of a data centre
  • What is the first issues of a data centre

Standards

  • TIA
  • ISO
  • Cenelec
  • BICSI

Availability

  • The "Tiers" or levels of availability
  • The standards definition
    • Design N + 1
    • Design S + S
    • Concurrently maintainable
    • Fault tolerant

Thermal management

  • Air conditioning
  • The concept of hot / cold aisles
  • Confined hot aisle
  • Confined cold aisle
  • Raised floor
  • Suspended ceiling
  • Cooling
  • Blade servers management

Power Management

  • Design
  • Generators
  • Uninterruptible Power Supplies
  • Power Distribution Units

Hardware

  • Cabinets
  • Racks
  • The top of row topology
  • The end of row topology

Bonding and grounding

  • Cabling system
  • Cabinets
  • Raised floor

Pathways

  • Topology
  • Data cabling system
  • Power cabling systems

Data cabling system

  • Topology
  • Unshielded cabling system
  • Shielded cabling system
  • Multimode fiber optic cabling system
  • Single mode fiber optic cabling system
  • Preconnectorized cabling system
  • 10Gbps Ethernet
  • 40Gbps Ethernet
  • 100Gbps Ethernet
  • Other technologies
  • Patching

Infrastructure management

  • Maintenance
  • Move, add and change

Green and data center efficiency

  • Virtualization
  • PUE & DCIE
  • Economies in Euros

Introduction to security

  • Fire protection
  • Video surveillance : The IP trend
    • Power over Ethernet
  • Access control : The IP trend

The Code of Conduct on Data Centres Energy Efficiency, European Commission, Directorate General Joint Research Centre, Institute for Energy, Renewable Energies Unit

  • Environmental statement
  • Aims and objectives
  • Commitments and monitoring

Price & Delivery methods

Online Training

Duration
3 days

Price
  • 2,495.— €
Classroom Training

Duration
3 days

Price
  • The Netherlands: 2,495.— €
  • Belgium: 2,495.— €

Schedule

Instructor-led Online Training:   This computer icon in the schedule indicates that this date/time will be conducted as Instructor-Led Online Training.
This is a FLEX course, which is delivered both virtually and in the classroom.

English

Time zone: Central European Time (CET)   ±1 hour

Online Training Time zone: Central European Time (CET)
This is a FLEX course, which is delivered both virtually and in the classroom.

Europe

France

Paris This is a FLEX course.   Time zone: Central European Time (CET) Enroll:
for online training
for classroom training
Paris This is a FLEX course.   Time zone: Central European Time (CET) Enroll:
for online training
for classroom training
Paris This is a FLEX course.   Time zone: Central European Summer Time (CEST) Enroll:
for online training
for classroom training
Paris This is a FLEX course.   Time zone: Central European Summer Time (CEST) Enroll:
for online training
for classroom training
Paris This is a FLEX course.   Time zone: Central European Time (CET) Enroll:
for online training
for classroom training